SENSOR ADJUSTMENT
The sensor comes factory preset and ready for operation.
If testing of operation is desired:
Remove the sensor’s cover (twist).
Refer to the DIP switch settings chart below for switch configurations.
Make sure that office furniture and fixtures are in place.
1. Restore power to the lighting circuits and turn the lights on.
There is a one minute warm-up when power is initially restored to the
sensor before the sensor works properly.
2. Set Time Delay to minimum: DIP switches #1 through 6 set to ON
(15 secs.).
3. Set Sensitivity to maximum: DIP switches
#7 and #8 to ON.
4. Replace the sensors cover.
5. Move away from sensor and be still.
The lights should go off after 15 seconds.
Note: If lights remain on, move farther away or out of sight of the sensor.
If lights still remain on, set the Sensitivity to medium high by setting DIP
switches #7 to ON and #8 to OFF, or see Unwanted Sensor Activations
under Troubleshooting.
6. Set the appropriate Time Delay (DIP switches #1 through 6).
The factory preset Time Delay is 18 minutes; other suggestions are:
Offices and conference rooms: 10 minutes.
Classrooms: 10 minutes.
Warehouses: 6 minutes.
Hallways: 4 minutes.
DIP SWITCH SETTINGS
LED
D
IP Switch Control
f
or Time Delay and
S
ensitivity
DIP Switch #
15 seconds
4 minutes
6 minutes
8 minutes
10 minutes
12 minutes
14 minutes
16 minutes
18 minutes
20 minutes
22 minutes
24 minutes
26 minutes
28 minutes
2 minutes
Minimum
Medium Low
Medium High
Maximum
1234 78
SensitivitySensitivity
56
30 minutes
= ON
= OFF
= Factory Presets